Abstract
We assessed three soluble fibrin monomer (SFM) assays in 231 in and out-patients with clinically suspected deep-vein thrombosis. Thrombosis was confirmed or excluded by complete lower-limb ultrasound. SFM assay were less accurate than VIDAS D-dimer and in patients with small thrombosis or under anticoagulation. Specificity was lower for a similar sensitivity.Figures & Tables
Article Information
Published
2004-01-01
Published By
Ferrata Storti Foundation, Pavia, Italy
Print ISSN
0390-6078
Online ISSN
1592-8721
Article Usage
Online Views
574
PDF Downloads
316
No Data