Abstract
Two versions of conformation sensitive gel electrophoresis, fluorescent (F-CSGE) and manual (M-CSGE) techniques, were compared for mutation analysis of the von Willebrand factor gene. 56 PCRs were used to amplify all 52 exons of the gene in seven type 1 von Willebrand disease cases, plus a healthy control. One hundred and ninety-two samples were analyzed on each F-CSGE gel, compared with 40 on M-CSGE. 125 amplicons revealed bandshifts using F-CSGE, but only 101 by M-CSGE. Five mutations were detected by both techniques. F-CSGE detected 45 different polymorphisms whereas M-CSGE detected only 39. F-CSGE is high-throughput and more sensitive than M-CSGE.Type 1 von Willebrand disease (VWD), a common autosomally inherited bleeding disorder, results from partial quantitative deficiency of plasma von Willebrand factor (VWF), and is the most common form of VWD accounting for 60%–80% of all cases.1,2 The VWF gene (VWF) is large and has proved challenging to screen for mutations. It covers 178kb, has 52 exons and is located at chromosome 12p13.3. A partial pseudogene, VWFP corresponding to exons 23-34 is present on chromosome 22q11.22-233,4 and complicates VWF analysis. Over 130 DNA polymorphisms have been reported in the coding and closely flanking intronic regions of VWF as detailed on the international VWF database (http://www.vwf.group.shef.ac.uk/).
Identification of disease-causing mutations in large genes such as VWF remains challenging in terms of speed, accuracy and cost-effectiveness. The gold standard for mutation detection is DNA sequencing, but for the large VWF gene, sequencing the entire coding region has not yet become routine. Several mutation screening techniques such as denaturing gradient gel electrophoresis (DGGE), single strand conformation polymorphism analysis (SSCP) and conformation sensitive gel electrophoresis (CSGE) can be used. Sensitivity estimates for detection of sequence variation using these methods range from 35% to 100%, depending on the size and sequence context of the DNA examined.5–7 Comparison of manual CSGE (M-CSGE), fluorescent CSGE (F-CSGE) and direct DNA sequencing for exon 11 of the BRCA2 gene in 16 individuals showed concordance of the results obtained by the three methods and established the high sensitivity of the F-CSGE.8 In the present study, we have utilized CSGE on a fluorescent platform to attempt to increase its throughput and sensitivity for mutation detection for patients enrolled in the Molecular and clinical markers for the diagnosis and management of type 1 VWD study (MCMDM-1VWD).9–11
Design and Methods
Study population
Index cases (IC) of seven European families who all had a personal and family history of type 1 VWD were analyzed. One healthy control (HC) was also included. All individuals were enrolled in the EU FP5 MCMDM-1VWD study.11
DNA extraction and amplification
DNA was extracted from citrate anticoagulated venous blood according to standard procedures. PCR amplification from genomic DNA was conducted on a Perkin-Elmer 480 thermocycler in a 50 μL volume. 52 exons and intron/exon boundaries plus the 3’ region of VWF were amplified in a mixture containing 1.1x Readymix PCR Master Mix (ABgene, Epsom, UK) with 1.5, 2.5 or 4.0 mmol/L MgCl2 and 50 nM of the appropriate primers as previously reported12–14 and listed on http://www.euvwd.group.shef.ac.uk/. Samples were initially denatured at 97°C for 5min, DNA amplification was achieved by 35 cycles of denaturation (95°C, 60 sec), annealing for 60 sec and extension (72°C, 90 sec).
Manual conformation sensitive gel electrophoresis (M-CSGE)
The method of Williams et al was used.15 Briefly, 5 μL of PCR product from each IC was mixed with an equal volume of PCR product from the HC. Samples were denatured at 98°C for 5min and then incubated at 65°C for 30 min to allow heteroduplex formation. For comparison, HC amplicons were self-heteroduplexed and 2–5 μL of heteroduplexed samples were loaded onto a 10% CSGE gel.
Fluorescent conformation sensitive gel electrophoresis (F-CSGE)
The method of Ganguly et al. was used.8 Briefly, each forward primer was labelled with FAM, HEX or TET fluorescent dye and on the basis of size/dye, the amplicons were divided into 19 groups of three (eg group 8; exons 7, 17 and 22) to enable multi-loading of products onto each gel lane. Heteroduplexes prepared as above were diluted from 1 to 15-fold (dependant on PCR product concentration) in deionized water followed by mixing 1 μL of each diluted heteroduplex with the two other heteroduplexes in the same group. Sample loading mix contained 1.5 μL of the three mixed PCR products with 0.5 μL size standard GenoTYPE ROX 50-500 (Applied Biosystems), 0.5 μL dextran blue (50 mg/mL) and 0.5 μLfreshly deionized formamide in a total volume of 3 μL. Of this mixture, 1.5 μL was loaded onto a 10% polyacrylamide gel consisting of 99:1 acrylamide:BAP (Fluka), 15% deionized formamide in 1xTBE. The gel was prepared in a final volume of 5 0ml and polymerized overnight with 0.6% (w/v) ammonium persulphate and 0.06% (v/v) TEMED. F-CSGE gels were 420 mm×250 mm in size and 0.2 mm thick. Sixty-four sharkstooth well combs were used to form wells. Electrophoresis was performed under mildly denaturing conditions at 2000Volts for 4.5 hours at 30ºC in 1xTBE with a 36cm well-to-read distance. Fragment size analysis software (Genescan and Genotyper, Applied Biosystems) was used for data analysis.
DNA sequencing
PCR products with aberrant CSGE patterns were analyzed using automated DNA sequencing (Applied Biosystems PRISM 377) according to the manufacturer’s instructions.
Results and Discussion
The coding region of the VWF gene of seven index cases from the MCMDM-1VWD study plus a control were screened for mutations using both fluorescent and manual CSGE. In total, 448 amplicons (8×56) were screened using both M- and F-CSGE. A hundred and one amplicons showed migration shifts using both techniques, while 24 amplicons in which shifts were unclear (smeared or very faint), or undetected by M-CSGE, were seen as migration shifts by F-CSGE. Migration shifts were seen in an average of 16 amplicons per individual using F-CSGE (range 12–19), but only 13 amplicons per individual using M-CSGE (range 10–16). Five candidate mutations were detected by both techniques, and are listed in Figure 1 (parts A to D).
F-CSGE detected shifts more efficiently than M-CSGE (Figure 1). For example, migration shifts detected using F-CSGE, were not detected (E) or were ambiguous (F) using M-CSGE. DNA sequencing confirmed the changes: a known single nucleotide polymorphism (SNP), c.4141G→A, in (E) and two different known SNPs in (F); heterozygous c.4641C→T plus homozygous c.4801C→A. DNA sequencing of amplicons demonstrating F-CSGE migration shifts revealed 49 different SNPs including eight novel changes, while 39 of the same SNPs were identified using M-CSGE. The eight novel changes were each located in different VWF introns. Apart from a false-positive result for exon 5 using both techniques, a low false-positive rate was seen only with F-CSGE. DNA sequencing did not reveal any nucleotide change in 4% (5/125) of amplicons demonstrating a F-CSGE migration shift.
In order to screen VWF for mutations in type 1 VWD, it was necessary to analyze at least 18.5 kb of DNA sequence per individual. It has been previously shown that mutation pre-screening followed by DNA sequencing for mutation identification in large genes is cost-effective and efficient.16 Using CSGE pre-screening in this study, and sequencing only 3 to 5kb of selected amplicons (10–15 amplicons/individual of 56 in total), delivered a high throughput method in terms of both time and cost saving in comparison with direct DNA sequencing alone. The multiload option was selected as a simple way to optimize F-CSGE gel use. PCR products were divided into groups of three amplicons and multi-loaded onto each gel lane. A hundred and ninety-two samples were analyzed on each 64 well gel, whereas only 40 samples were analysed on each M-CSGE gel.
The sensitivity of any mutation scanning method is determined by its ability to detect and distinguish between different single-base substitutions. The length of the M-CSGE gel was 41cm and sample migration was 25 to 35cm after 17 hours (depending on amplicon size) when the gel was documented. In F-CSGE, all amplicons migrated the full length of the gel (36cm) and were detected at its base. The increased migration length leads to enhanced resolution. Figure 1 (G and H) demonstrates the ability of F-CSGE to detect different nucleotide substitutions in the same amplicon, through different peak sizes. F-CSGE detected insertions and deletions as well as single base substitutions in this study, as previously reported.8,17,18
Ten amplicons gave shifts identified as sequence alterations for some or all individuals using F- but not M-CSGE (those for exons 4, 14, 18, 19, 24, 28-2, 28-3, 28-4, 35 and 39). Most discrepancies were amplicon- and not patient- specific. Some, such as those for amplicons 28-4 and 35 were subtle changes that were missed by M-CSGE due to a minor migration change, but were identifiable using F-CSGE due to automated size-calling of the shifted peak. Analysis of the size and GC content of these ten amplicons did not show any common feature to be responsible for lack of sensitivity of M-CSGE (size 217-478bp, GC content 47–65%).
A false-positive result for exon 5 was demonstrated for both techniques. Migration shifts in all samples were not associated with sequence alteration. A small number of other false-positive results were seen in F-CSGE, but no common features of amplicons giving rise to F-CSGE shifts were identified. False-negative results are difficult to quantitate, but overall in the MCMDM-1VWD study, candidate mutations were found in 105 out of 150 IC (70%) using techniques including CSGE, SSCP, DHPLC and DNA sequencing.11 This is similar to the detection rate in this small sub-group. Significant improvements from modifying the methodology to the fluorescent platform resulted in a higher throughput, reproducible and more rapid method than M-CSGE, with enhanced resolving power for seeking sequence alteration in the large VWF gene. The utility of F-CSGE has been recognized by its adaptation for use on capillary sequencers as fluorescent conformation sensitive capillary electrophoresis.19,20
Acknowledgments
This work was undertaken as part of the European Union collaborative study Molecular and Clinical Markers for the Diagnosis and Management of Type 1 von Willebrand Disease; MCMDM-1VWD.
Footnotes
- ↵* Current address: Medical Faculty and Thalassaemia Research Center, Mazandaran University of Medical Sciences, Sari, Mazandaran, Iran.
- Author Contributions AG and IP initiated and co-ordinated the study. All authors participated in study design, data collection and performing laboratory analyses. HSSMB analyzed and interpreted results. HSSMB and AG wrote the paper, and all authors checked the final version of the manuscript.
- Conflict of Interest The authors reported no potential conflicts of interest.
- Received August 2, 2006.
- Accepted February 15, 2007.
References
- Sadler JE, Mannucci PM, Berntorp E, Bochkov N, Boulyjenkov V, Ginsburg D. Impact, diagnosis and treatment of von Willebrand disease. Thromb Haemost. 2000; 84:160-74. Google Scholar
- Castaman G, Federici AB, Rodeghiero F, Mannucci PM. von Willebrand’s disease in the year 2003: towards the complete identification of gene defects for correct diagnosis and treatment. Haematologica. 2003; 88:94-108. Google Scholar
- Mancuso DJ, Tuley EA, Westfield LA, Worrall NK, Shelton-Inloes BB, Sorace JM. Structure of the gene for human von Willebrand factor. J Biol Chem. 1989; 264:19514-27. Google Scholar
- Mancuso DJ, Tuley EA, Westfield LA, Lester-Mancuso TL, Le Beau MM, Sorace JM. Human von Willebrand factor gene and pseudogene: structural analysis and differentiation by polymerase chain reaction. Biochemistry. 1991; 30:253-69. Google Scholar
- Körkkö J, Annunen S, Pihlajamaa T, Prockop DJ, Ala-Kokko L. Conformation sensitive gel electrophoresis for simple and accurate detection of mutations: comparison with denaturing gradient gel electrophoresis and nucleotide sequencing. Proc Natl Acad Sci USA. 1998; 95:1681-5. Google Scholar
- Markoff A, Sormbroen H, Bogdanova N, Preisler-Adams S, Ganev V, Dworniczak B. Comparison of conformation-sensitive gel electrophoresis and single-strand conformation polymorphism analysis for detection of mutations in the BRCA1 gene using optimized conformation analysis protocols. Eur J Hum Genet. 1998; 6:145-50. Google Scholar
- Eng C, Brody LC, Wagner TM, Devilee P, Vijg J, Szabo C. Interpreting epidemiological research: blinded comparison of methods used to estimate the prevalence of inherited mutations in BRCA1. J Med Genet. 2001; 38:824-33. Google Scholar
- Ganguly T, Dhulipala R, Godmilow L, Ganguly A. High throughput fluorescence-based conformation-sensitive gel electrophoresis (F-CSGE) identifies six unique BRCA2 mutations and an overall low incidence of BRCA2 mutations in high-risk BRCA1-negative breast cancer families. Hum Genet. 1998; 102:549-56. Google Scholar
- Tosetto A, Rodeghiero F, Castaman G, Goodeve A, Federici AB, Batlle J. A quantitative analysis of bleeding symptoms in type 1 von Willebrand disease: results from a multicenter European study (MCMDM-1 VWD). J Thromb Haemost. 2006; 4:766-73. Google Scholar
- Eikenboom J, Van Marion V, Putter H, Goodeve A, Rodeghiero F, Castaman G. Linkage analysis in families diagnosed with type 1 von Willebrand disease in the European study, molecular and clinical markers for the diagnosis and management of type 1 VWD. J Thromb Haemost. 2006; 4:774-82. Google Scholar
- Goodeve A, Eikenboom J, Castaman G, Rodeghiero F, Federici AB, Batlle J. Phenotype and genotype of a cohort of families historically diagnosed with Type 1 von Willebrand Disease in the European study, molecular and clinical markers for the diagnosis and management of Type 1 von Willebrand Disease (MCMDM-1VWD). Blood. 2007; 109:112-21. Google Scholar
- Zhang ZP, Falk G, Blomback M, Egberg N, Anvret M. Identification of a new nonsense mutation in the von Willebrand factor gene in patients with von Willebrand disease type III. Hum Mol Genet. 1992; 1:61-2. Google Scholar
- Zhang ZP, Blomback M, Nyman D, Anvret M. Mutations of von Willebrand factor gene in families with von Willebrand disease in the Aland Islands. Proc Natl Acad Sci USA. 1993; 90:7937-40. Google Scholar
- Allen S, Abuzenadah AM, Blagg JL, Hinks J, Nesbitt IM, Goodeve AC. Two novel type 2N von Willebrand disease-causing mutations that result in defective factor VIII binding, multimerization, and secretion of von Willebrand factor. Blood. 2000; 95:2000-7. Google Scholar
- Williams IJ, Abuzenadah A, Winship PR, Preston FE, Dolan G, Wright J. Precise carrier diagnosis in families with haemophilia A: use of conformation sensitive gel electrophoresis for mutation screening and polymorphism analysis. Thromb Haemost. 1998; 79:723-6. Google Scholar
- Ganguly A, Williams C. Detection of mutations in multi-exon genes: comparison of conformation sensitive gel electrophoresis and sequencing strategies with respect to cost and time for finding mutations. Hum Mutat. 1997; 9:339-43. Google Scholar
- Spitzer E, Abbaszadegan MR, Schmidt F, Hauser A, Buwitt U, Lauter FR. Detection of BRCA1 and BRCA2 mutations in breast cancer families by a comprehensive two-stage screening procedure. Int J Cancer. 2000; 85:474-81. Google Scholar
- Blesa JR, Hernandez-Yago J. Adaptation of conformation-sensitive gel electrophoresis to an ALF express DNA sequencer to screen BRCA1 mutations. Biotechniques. 2000; 28:1019-25. Google Scholar
- Ganguly A. An update on conformation sensitive gel electrophoresis. Hum Mutat. 2002; 19:334-42. Google Scholar
- Rozycka M, Collins N, Stratton MR, Wooster R. Rapid detection of DNA sequence variants by conformation-sensitive capillary electrophoresis. Genomics. 2000; 70:34-40. Google Scholar